title-border-no">
Our Transformer Spare Components
We are supplying a wide range of transformer spares as per customer requirements for all kinds of transformers and On Load Tap changers.

Pressure Relief value or pressure relief device (PRV)
Pressure Relief Valve (PRV) is
safeguarding the transformer
against excessive oil pressure
accumulation in the event of a
fault.

Buchholz Relay or Gas Actuated Relay
The Buchholz Relay functions as an alert system sensitive to internal transformer faults.

Oil Level Indicator or Magnetic Oil Level Gauge (MOG)
Magnetic Oil Level Indicator (MOG) is designed to display the transformer insulating oil level in the conservator of transformer.

Porcelain Bushing
Porcelain bushing is an insulating structure that enables an energized, current-carrying conductor to pass through the grounded tank of the transformer.

On Load Tap changer or OLTC
On-Load Tap Changer adjusts transformer voltage to stabilize output amidst load and supply variations.

Transformer Radiator Valve or Shut off Valve
Transformer radiator valve is a control device used to regulate the flow of cooling oil through the transformer’s radiator, ensuring efficient cooling and temperature control.

Transformer Drain Valve or Gate Valve or Globe Valve
Transformer drain valve are essential control devices used for managing the draining of oil or controlling the flow within a transformer system.

Silica Gel Breather
A Silica Gel Breather contains silica gel crystals to absorb moisture from the air entering the transformer’s conservator tank, preserves transformer oil quality by moisture absorption.

Oil and Winding Temperature Indicator
Analog Oil and Winding Temperature Indicator is a gauge that provides a visual representation of the transformer oil’s and winding temperature on a traditional analog scale

Transformer Oil or Insulating Oil
Transformer oil is a specialized dielectric fluid used in transformers to provide electrical insulation and efficient cooling, ensuring safe and reliable operation of the transformer.

Gasket and Oring Sets
Gasket and Oring Sets are sealing materials placed between mating components to prevent leakage of oil or gas, Preserving transformer integrity and performance.

Cooling Fan
Transformer cooling fan is a
mechanical device used to
enhance the cooling process by increasing airflow over the
transformer’s radiator or cooling fins.

Oil Surge Relay (OSR)
The Oil Surge Relay acts as a
protective device, responding to sudden oil surges within a
transformer.

Aircell or Flexi Separators
Aircell is engineered to serve as a partition, keeping unwanted contaminants in the atmosphere from coming into contact with transformer oil inside a conservator

Conservator Protection Relay (CPR)
The Conservator Protection Relay (CPR) is a dedicated protective device created to identify Aircell leaks by generating electrical
signals

Gas Collecting Device (GCD)
Gas Collecting Device is an
attachment connected to the gas collection petcock of the Buchholz Relay, Easily collect Gas and Oil samples from the relay.

CT Terminal Box (TBX)
Terminal Box (TBX) provides a quick, reliable connection solution for linking CT wires inside.

CFT Terminal Box (CFT)
CFT is intended for establishing a ground connection between the
transformer’s core and frame.

Flow Indicator
The Flow Indicator is primarily crafted as a safety device, ensuring an electrical signal in case of forced.

Prismatic Oil Level Indicators
Prismatic Oil Liquid Level Indicators for Transformers are monitoring devices that display the current oil.

Pressure Gauge
A Pressure Gauge is a measuring device that displays the pressure of the insulating oil within the
transformer.

Off Load Tap changer or De energised Switch
An Off-Load Tap Changer is a switching mechanism used to adjust the transformer’s tap settings without load or power flow, Optimizing voltage when transformer’s inactive.

Remote Indicator (OTI/WTI)
A Remote Indicator is a monitoring device that displays the Oil Temperature Indicator (OTI) and Winding Temperature Indicator (WTI) readings from a remote location.

Automatic Voltage Regulator (AVR)
An Automatic Voltage Regulator is an essential control device that automatically adjusts and stabilizes the output voltage to maintain a consistent and reliable electrical supply.

Annunciator
An Annunciator is a visual or audible alert system that provides notifications or warnings about specific conditions or events occurring in the transformer.

Tap Position Indicator
A Tap Position Indicator is a device that visually or electronically indicates the current position of the tap changer on the transformer.

RTCC Panel
Remote Tap Changer Control Panel is a control and monitoring system that remotely regulates the tap changer settings on a transformer

Marshalling Box
A Marshalling Box for transformers is an enclosure or junction box used to organize and route various control and monitoring cables.

Radiator
A radiator for transformers is a heat exchange device that dissipates excess heat generated during the transformer’s operation.

Bushing CT (BCT)
A Bushing CT (Current Transformer) for transformers is an instrument that measures the electrical current passing through a transformer bushing.

Copper Flat
Copper flat for transformers refers to flat-shaped copper conductors used within transformers for efficient electrical conductivity

Oil Pump
A transformer oil pump is a mechanical device responsible for circulating and maintaining the proper flow of insulating oil within the transformer

Roller or Transformer Wheels
Rollers or transformer wheels are mechanical components attached to the base of a transformer, allowing for easy mobility and transportation

Epoxy Bushing
An epoxy bushing for transformers is an insulating component made of epoxy resin, which provides insulation and conductor support.

Rapid Pressure Rise relay
A Rapid Pressure Rise Relay is a protective device designed to detect and respond to sudden increases in pressure within the transformer

Oil Pump
A Heat Exchanger for transformers is a component that helps regulate the temperature of the transformer’s insulating oil by dissipating excess heat.

Heat Exchanger
A Heat Exchanger for transformers is a component that helps regulate the temperature of the transformer’s insulating oil by dissipating excess heat